Code: SC314
Description: Drum Potential Sensor Error 5 (Vh Abnormal)
When adjusting the drum potential (Vh) for LD power adjustment during process control initial setting, the first time the Vh pattern is made, the drum potential sensor detects that Vh is more than 600 V. NOTE: After this SC is issued, the grid voltage changes to the value set with SP2001-001 (Charge Corona Bias Adjustment) and LD power changes to the value set with SP2103 (LD Power Adjustment).
When adjusting the drum potential (Vh) for LD power adjustment during process control initial setting, the first time the Vh pattern is made, the drum potential sensor detects that Vh is more than 600 V. NOTE: After this SC is issued, the grid voltage changes to the value set with SP2001-001 (Charge Corona Bias Adjustment) and LD power changes to the value set with SP2103 (LD Power Adjustment).
Causes: • Drum worn • Drum potential sensor defective • Poor drum potential sensor connection • Drum potential sensor connector defective • LD unit requires cleaning • IOB defective • Drum unit connector defective • LDB board defective