Code: E001
Description: The fixing assembly suffers from abnormally high temperature
• The fixing temperature exceeds about 230°C during standby or during copying operation.
• The fixing temperature exceeds about 230°C during standby or during copying operation.
Remedy: Thermistor 1) Turn off the power switch, and remove the fixing assembly. Then, measure the resistance between connectors J50B-2 (FSRTH) and J50B-3 (GNDTH) of the fixing assembly side. Is the resistance 1k Ohm or less? NO: Check the wiring from J222 on the DC controller PCB to the thermistor; if normal, replace the thermistor. Power supply assembly, DC controller PCB 2) Replace the power supply assembly. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.