Code: E003
Description: The fixing assembly suffers from abnormally low temperature.
• The fixing temperature drops below 120°C after it has reached the target temperature.
• The fixing temperature drops below 120°C after it has reached the target temperature.
Remedy: Thermistor 1) Is the thermistor soiled? YES: Clean the thermistor. Is the thermistor in even contact with the fixing upper roller? NO: Mount the thermistor correctly. Turn off the power switch, and remove the fixing assembly. Measure the resistance between connectors J50B-2 (FSRTH) and J50B- 3 (GNDTH) on the fixing assembly side. Is it between 120k and 290k Ohm NO: Check the wiring from J222 on the DC controller PCB to the thermistor; if normal, replace the thermistor. Main heater 2) With the fixing assembly removed, is there electrical continuity between connectors J50-3 (FSRN1) and J50-5 (FSRL1) on the fixing assembly side? NO: Replace the main heater. Sub heater 3) With the fixing assembly removed, is there electrical continuity between connectors J50-4 (FSRN2) and J50-5 (FSRL2) on the fixing assembly side? NO: Replace the sub heater. Thermal switch, DC controller PCB 4) Remove the fixing assembly, and detach the wiring cover. Is there electrical continuity between the terminals of the thermal switch? NO: Replace the thermal switch. YES: Replace the DC controller PCB