Code: E010
Description: The main motor fails to start up normally
• The revolution of the main motor fails to reach a specific revolution.
• The revolution of the main motor fails to reach a specific revolution.
Remedy: Connector 1) Is connector J12 of the main motor and connector J218 on the DC controller PCB connected correctly? YES: Connect them correctly. Switch, Door switch of sensor PCB 2) Disconnect connectors J205 and J221 from the DC controller PCB. Is there electrical continuity between J205-3 (+24 V) and J221-1 (+24 VB) on the harness side when the door switch (SW1401) is turned on? NO: Replace the switch/sensor PCB. Main motor, DC controller PCB 3) Can the main motor be rotated using a printer driver checker? NO: Replace the main motor.