Code: E676
Description: The PDL PCB has a communication error.
• The communication with the PDL PCB fails in initialization sequence. • The registration of the PDL-unique menu fails. • While PDL is in operation, a check sum error of the received packet is detected. • While PDL is in operation, a format error in the received packet is detected. • There is no response in the course of a check on the PDL board operation.
• The communication with the PDL PCB fails in initialization sequence. • The registration of the PDL-unique menu fails. • While PDL is in operation, a check sum error of the received packet is detected. • While PDL is in operation, a format error in the received packet is detected. • There is no response in the course of a check on the PDL board operation.
Remedy: Connector (poor contact) 1) Is the PDL PCB securely connected to J303 of the relay PCB? NO: Connect it securely. Relay PCB 2) Are connector J301 of the relay PCB and connector J1017 of the system controller PCB connected securely? NO: Connect the connectors securely. PDL PCB, System controller PCB 3) Try replacing the PDL PCB. Is the problem corrected? YES: End. NO: Replace the system controller PCB.