Code: E677
Description: The PDL PCB is faulty.
• An error occurs on the PDL board.
• An error occurs on the PDL board.
Remedy: Connector (poor contact) 1) Is the PDL PCB securely connected to J303 of the relay PCB? NO: Connect it securely. Relay PCB 2) Are connector J301 of the relay PCB and connector J1017 of the system controller PCB connected securely? NO: Connect the connectors securely. PDL PCB, System controller PCB 3) Try replacing the PDL PCB. Is the problem corrected? YES: End. NO: Replace the system controller PCB.