Code: E712
Description: An error occurs in IPC communication.
• In communication with the ADF, four or more errors occur in 1.5 sec or more.
• In communication with the ADF, four or more errors occur in 1.5 sec or more.
Remedy: 1) Turn off and then on the power. Is the problem corrected? YES: End. If the problem occurs frequently, check the communication cable to the finisher. Connector (poor contact) 2) Is the connection between the machine and the finisher secure? NO: Make the connection secure. Communication cable 3) Try replacing the communication cable to the finisher. Is the problem corrected? YES: End. Finisher controller PCB, System controller PCB 4) Try replacing the finisher controller PCB of the finisher. Is the problem corrected? YES: End. NO: Replace the system controller PCB.