Code: E713
Description: An IPC finisher error occurs.
• The communication between the finisher and the machine remiains interrupted for 3 sec.
• The communication between the finisher and the machine remiains interrupted for 3 sec.
Remedy: 1) Turn off and then on the power. Is the problem corrected? YES: End. If the problem occurs frequently, check the communication cable to the finisher. Connector (poor contact) 2) Is the connection between the machine and the finisher secure? NO: Make the connection secure. Communication cable 3) Try replacing the communication cable to the finisher. Is the problem corrected? YES: End. Finisher controller PCB, System controller PCB 4) Try replacing the finisher controller PCB of the finisher. Is the problem corrected? YES: End. NO: Replace the system controller PCB.