Code: E733
Description: A controller printer unit communication error occurs.
• The PPRDY signal cannot be detected from the printer unit 15 sec after the end of start-up sequence.
• The PPRDY signal cannot be detected from the printer unit 15 sec after the end of start-up sequence.
Remedy: Connector (poor contact) 1) Is the controller unit mounted to the printer unit securely? NO: Mount it correctly. 2) Are connector J1015 on the system controller PCB and connector J501 on the image processor PCB connected securely? NO: Connect the connectors securely. Printer unit power supply 3) Does the printer unit execute initialization when the power is turned on? NO: See “The printer unit power supply is absent.” DC controller PCB 4) Can the printer unit be operated using the printer checker driver? NO: Replace the DC controller PCB Controller unit 5) Try replacing the image processor PCB. Is the problem corrected? YES: Replace the image processor PCB. NO: System controller PCB