Code: E738
Description: A network interface initialization error occurs.
• Initialization of the network PCB fails at power-on.
• Initialization of the network PCB fails at power-on.
Remedy: Connection (poor contact) 1) Is the network PCB connected to the relay PCB securely? NO: Connect it securely. Relay PCB 2) Is connector J301 of the relay PCB connected to connector J1017 of the system controller PCB securely? NO: Connect the connector securely. Network PCB 3) Try replacing the network PCB. Is the problem corrected? YES: End. Relay PCB, System controller PCB 4) Try replacing the relay PCB. Is the problem corrected? YES: End. NO: Replace the system controller PCB.