Mã lỗi E000-0000 — Canon iR3300

Code: E000-0000

Description: The reading of the main thermistor does not reach 30C 1 sec after the main power switch is turned on. Or, it does not reach 70C 2 sec thereafter
Causes: The fixing film unit is faulty. The main thermistor has an open circuit. The fixing heater has an open circuit. The main power supply PCB is faulty. The DC controller PCB is faulty. To reset the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR.
Remedy: 1. Connector Is the connector of the fixing assembly connected? a. main power supply PCB (J8) <-> relay connector <-> heater b. DC controller PCB (J320) <-> relay connector <-> thermistor NO: Connect the connector. 2. Fixing film unit (thermistor) Check the interval between pin 1 and pin 2 and between pin 3 and pin 4 of the connectosr (4-pin) of the thermistor for electrical continuity. Is it W (open)? YES: The heater has an open circuit, or the thermal switch is open. Replace the fixing film unit. 4. Main power supply PCB, DC controller PCB Press the Start key. Is the drive voltage of the heater supplied by the connector J8 of the main power supply PCB? Main heater: between J8-1 (FSR1) and J8-5 (FSR COM) Sub heater: between J8-3 (FSR2) and J8-5 (FSR COM) YES: The heater drive power supply is faulty. Replace the main power supply PCB. NO: The thermistor control mechanism is faulty. Replace the DC controller PCB.

← Xem tất cả mã lỗi Canon iR3300

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie