Code: E064-0000
Description: The presence of a high-voltage error is communicated by the composite power supply PCB (The output for primary charging, developing, or transfer has deviated from a specific level of voltage)
Causes: The contact has poor connection. The wiring is faulty. The composite power supply PCB is faulty. The DC controller PCB is faulty. proce
Remedy: 1. Contact Is any of the contacts of the primary charging roller, developing assembly, or transfer charging roller soiled? Or, is there poor contact? YES: Clean the contact, and set it once again. 2. Wiring Is the wiring between the contacts for the following normal: DC controller PCB (J301), composite power supply PCB (J136), primary charging roller, developing assembly, transfer charging roller? a. DC controller PCB (J301) <-> composite power supply PCB (J136) b. composite power supply PCB (J130-7) <-> primary charging roller contact c. composite power supply PCB (J130-1) <-> developing assembly contact d. composite power supply PCB (FT133) <-> transfer roller contact NO: Correct the connection. 3. Composite power supply PCB, DC controller PCB Try replacing the composite power supply PCB. Is the problem corrected? YES: Yes. NO: Replace the DC controller PCB.