Description: The BD signal is not detected 10 times or more within 10 msec in 5 msec after the generation of the laser drive signal
Causes: The wiring is faulty (short circuit, open circuit). The BD PCB is faulty. The laser scanner unit is faulty. The DC controller PCB is faulty.
Remedy: 1. BD PCB Try replacing the BD PCB. Is the problem corrected? YES: End. 2. Laser scanner unit, DC controller PCB Try replacing the laser scanner unit. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.