Code: E007-0000
Description: An error in the rotation of the fixing film is detected.
The reading of the main thermistor is 100C or higher and, in addition, the fixing film sensor does not detect the rotation of the film for 6 sec or more while the fixing motor is driven
The reading of the main thermistor is 100C or higher and, in addition, the fixing film sensor does not detect the rotation of the film for 6 sec or more while the fixing motor is driven
Causes: The fixing film sensor (PS45) is faulty. The DC controller PCB is faulty. Caution To clear the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR
Remedy: 1. Wiring Are the wring and the connectors connected securely? DC controller PCB (J311) <-> relay connector <-> fixing film sensor NO: Connect the wiring and the connectors. 2. Fixing film sensor Check the fixing film rotation signal.When the fixing motor is rotating, is the film rotation detection signal sent by the fixing film sensor to the concoctor J311 of the DC controller PCB? Film rotation detection signal: 5V pulse signal between J311-A9 (FILM_ROT_D) and J311-A8 (GND); at intervals of 100 msec ON and 440 msec OFF NO: If the fixing film is normal, replace the sensor. 3. Fixing film unit, DC controller PCB Is there a fault in the fixing film edge rotation detection mechanism? YES: Replace the fixing film unit. NO: Replace the DC controller PCB.