Description: Data is written to the error register of the communication IC (IPC) on the reader controller PCB four times or more within 1.5 sec
Causes: The connector has poor connection. The ADF controller PCB is faulty. The finisher controller PCB is faulty. The DA unit PCB is faulty. The card reader PCB is faulty.
Remedy: Connector, ADF controller PCB Is the interface cable between the ADF controller PCB an the reader controller PCB normal? NO: Correct the cable. YES: Replace the ADF controller PCB.