Code: SC353
Description: ID Sensor Error 4 (Adjustment Error)
One of the following ID sensor output voltages is detected at ID sensor initialization. 1) VSG < 4.0 V when the maximum PWM input (255) is applied to the ID sensor. 2) VSG >= 4.0 V when the minimum PWM input (0) is applied to the ID sensor. NOTE: 1) The most recent PWM value is used for control. 2) The values displayed with SP3103 (ID Sensor Output Display) are the actual values.
One of the following ID sensor output voltages is detected at ID sensor initialization. 1) VSG < 4.0 V when the maximum PWM input (255) is applied to the ID sensor. 2) VSG >= 4.0 V when the minimum PWM input (0) is applied to the ID sensor. NOTE: 1) The most recent PWM value is used for control. 2) The values displayed with SP3103 (ID Sensor Output Display) are the actual values.
Causes: • ID sensor defective • ID sensor harness defective • ID sensor connector defective • IOB defective • LD unit defective • BCU defective • CBG power pack defective • Dirty ID sensor