Description: Oil Supply/Cleaning Web End
The oil supply/cleaning web end sensor stays on longer than the specified time after the web motor remains ON for 40 s.
Causes: • Oil supply/cleaning web end (web on supply roller used up) • Oil supply/cleaning web motor defective NOTE: SP1902 001 (Web Motor Control . Web Consumption) should be set to .0. every time the oil supply/cleaning web is replaced. This setting will not take effect until the machine is cycled off/on.