Code: E002-0010
Description: The rise in the temperature of the fixing assembly is not enough. There is an open circuit or poor contact in the main thermistor (THM1, THM2, THM3), thermal switch (TP1, TP2, TP3), or heater (H1, H2, H3, H4). The AC driver PCB or the DC controller PCB has a fault.
The temperature of the fixing roller reaches 80 deg C, but drops below 50 deg C.
The temperature of the fixing roller reaches 80 deg C, but drops below 50 deg C.
Remedy: Check the main thermistor, thermal switch, and heater for an open circuit and poor contact; then, reset in service mode: COPIER>FUNCTION>CLEAR>ERR.