Code: 390
Description: Development Bias output error
The high voltage supply board (C/B) monitors the circuit and detects abnormal conditions such as a voltage leak or no output condition. If this happens, the high voltage supply board sends an error signal (High to Low at CN204A18) to the BCU. The BCU monitors this signal every 2 ms and generates this SC code when the error condition occurs 250 consecutive times.
The high voltage supply board (C/B) monitors the circuit and detects abnormal conditions such as a voltage leak or no output condition. If this happens, the high voltage supply board sends an error signal (High to Low at CN204A18) to the BCU. The BCU monitors this signal every 2 ms and generates this SC code when the error condition occurs 250 consecutive times.
Causes: • Loose connection • Defective power pack C/B output • Damaged cable • Defective development unit • Defective BCU