Code: 391
Description: Charge AC output error
391-01: K 391-02: Y 391-03: M 391-04: C The high voltage supply board sends the feedback signal (CN228-2 to 5; MCYK). The BCU monitors these feedback signals every 8 ms. If the average of the sampled data is not within the control target 20 consecutive times, this SC code is generated.
391-01: K 391-02: Y 391-03: M 391-04: C The high voltage supply board sends the feedback signal (CN228-2 to 5; MCYK). The BCU monitors these feedback signals every 8 ms. If the average of the sampled data is not within the control target 20 consecutive times, this SC code is generated.
Causes: • Power pack disconnected • Charge receptacle or terminal • Defective PCU bias input terminal • Incorrect power pack B/C output • Damaged cable • Defective BCU • PCU not found