Code: E355-0001
Description: Serial No. mismatch PCB.
The soft IDs of the following pairs are not identical and, in addition, any of the following conditions exist: SEEPROM and SRAM1, SEEPROM and SRAM2, SEEPROM and FRAM. - FRAM is of the initialization pattern (i.e., the value of the check sum area is '1', and the result of check sum computation of the counter area is '1'). - the soft ID of any of the following is not identical: SRAM1, SRAM2, FRAM.
The soft IDs of the following pairs are not identical and, in addition, any of the following conditions exist: SEEPROM and SRAM1, SEEPROM and SRAM2, SEEPROM and FRAM. - FRAM is of the initialization pattern (i.e., the value of the check sum area is '1', and the result of check sum computation of the counter area is '1'). - the soft ID of any of the following is not identical: SRAM1, SRAM2, FRAM.
Remedy: Reset E355 (if the error occurs in the middle of repair operation). At times, E355 cannot be reset (intentionally designed in such a way to prevent illegal replacement in the field).