Description: The fixing unit has overheated. After correcting the error, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The reading of the main thermistor has exceeded 100 deg C, but does not reach 150 deg C within 2.5 min thereafter)
Remedy: Disconnect and then connect J508 of the DC controller PCB. Disconnect and then connect the connectors of the fixing unit. Check the wiring between the main/sub thermistor and the DC controller. Check the mounting/soiling of the main thermistor. Replace the fixing heater. Replace the AC driver PCB. Replace the DC controller PCB.