Code: E012-0002
Description: Error in activation of motor Y
When 2.5 sec passed after activation of the yellow drum motor, the cycle of drum motor speed detection signal does not become its specified value.
When 2.5 sec passed after activation of the yellow drum motor, the cycle of drum motor speed detection signal does not become its specified value.
Causes: Error in drum motor, error in DC controller PCB.
Remedy: - Replacement of drum motor - Replacement of DC controller PCB