Code: 543
Description: Fusing Lamp Overheated: Error 1 (Software)
A fusing temperature more than 230 °C (446°F) was detected 3 times (measured at 180 ms intervals). Note: A shorted triac or other problem could cause the fusing lamp to stay on.
A fusing temperature more than 230 °C (446°F) was detected 3 times (measured at 180 ms intervals). Note: A shorted triac or other problem could cause the fusing lamp to stay on.
Causes: • Replace the MCU.