Code: E012
Description: XX=01: Y, XX=02: M, XX=03: C, XX=04: Bk (XX indicates the developing assembly color) XX01 The target speed cannot be attained even when the frequency of the motor drive pulse is increased to the upper limit. XX02 The target speed cannot be attained even when the frequency of the motor drive pulse is decreased to the lower limit. XX03 The encoder signal from the motor is not generated for the following period of time: standard: 3.69 msec, 1/2 speed: 7.38 msec, 1/4 speed: 14.75 msec XX04 The motor rotates in the direction opposite the desired direction. XX05 The spatial displacement is not corrected even when the frequency of the motor drive pulse is varied. XX06 The target speed cannot be attained even when the frequency of the motor drive pulse is varied. XX07 Not used. XX08 Not used. XX09 An error has occurred in the communication with the DC controller PCB.
Causes: The drum motor (M3, M4, M5, M6) is faulty. The drum motor drive system has an excess load. The DC controller PCB is faulty.