Code: E244
Description: x=0: Pickup assembly PCB, 1: Serial driver PCB, 2: Duplex driver PCB y=0 to 7: Port of each PCB xy01 Connection check error When the main power switch is turned on, communication with each PCB cannot be established. xy02 Parity error After communication with each PCB has been established, a parity error has occurred continuously 5 times. xy04 Sub station reset response time-out error When the main power switch is turned on, each PCB cannot be reset (reset processing error). xy05 Connection check result response time-out error When the main power switch is turned on, communication with each PCB cannot be established. xy06 Transmission end response time-out error After communication has been established with each PCB, the absence of responce has occurred continuously 5 times. (monitoring at tall times)
Causes: The pickup assembly PCB is faulty. The serial driver PCB is faulty. The duplex driver PCB is faulty. The DC controller PCB is faulty.