Mã lỗi E020 — Canon iRC2100S

Code: E020

Description: XX=01: Y, XX=02: M, XX=03: C, XX=04: Bk (XX indicates the developing assembly color) XXA0During printing sequence, the difference between the maximum value and the minimum value of SIGNAL (9 samplings) is 0.2 V (10) or less. XX80 During printing sequence, the value of INIT-SIGNAL entered as part of initial settings has dropped to 2.344 V (120) or lower. XX81 During printing sequence, the value of INIT-SIGNAL entered as part of initial settings has risen to 2.656 V (136) or higher. XX90 During printing sequence, the correction value for INIT-SIGNAL has changed to 0 (in service mode, ADJUST>DENS>SIGG-Y/M/ C/K). XX91 During printing sequence, the correction value for INIT-SIGNAL has changed to 255 (in service mode, ADJUST>DENS>SIGG-Y/ M/C/K). XXB0 During printing sequence, the value of SIGNAL obtained by sampling and averaging is 0.43 V (22) or lower. XXB1 During printing sequence, the value of SIGNAL obtained by sampling and averaging is 4.9 V (250) or higher. XXD0During printing sequence, the value of SIGNAL remains higher than INIT-SIGNAL entered as part of initial settings by 4.71 V (240) or more continuously for 10 prints. XXE0 During printing sequence, the value of SIGNAL remains lower than INIT-SIGNAL entered as part of initial settings by 0.98 V (50) or more continuously for 10 prints.
Causes: The ATR sensor connector is disconnected. The developing cylinder/stirring screw fails to rotate.

← Xem tất cả mã lỗi Canon iRC2100S

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie