Code: E003-0000
Description: Error in abnormally low temperature of fixing assembly
The status where the detected temperature of the main thermistor is 100 deg C (approx. 2.60V equivalent) or less is detected for 0.5 continuous sec or more.
The status where the detected temperature of the main thermistor is 100 deg C (approx. 2.60V equivalent) or less is detected for 0.5 continuous sec or more.
Causes: Error in low-voltage power supply PCB, disconnection of main thermistor, error in DC controller PCBor 20 msec.
Remedy: - Replacement of low-voltage power supply PCB - Replacement of fixing sleeve unit - Replacement of DC controller PCB