Code: 731
Description: Finisher motor error
The meaning of this SC error depends on which finisher is installed. 1000-sheet Finisher B408 Exit guide plate motor error. The exit guide plate open sensor or exit guide plate HP sensor does not activate within a certain time after the exit guide plate motor turned on. (1000-sheet finisher) 500-sheet Finisher B442 Output tray motor error. The tray upper limit sensor does not activate within a certain time after the shift motor turned on. (500-sheet finisher)
The meaning of this SC error depends on which finisher is installed. 1000-sheet Finisher B408 Exit guide plate motor error. The exit guide plate open sensor or exit guide plate HP sensor does not activate within a certain time after the exit guide plate motor turned on. (1000-sheet finisher) 500-sheet Finisher B442 Output tray motor error. The tray upper limit sensor does not activate within a certain time after the shift motor turned on. (500-sheet finisher)
Causes: 1000-sheet Finisher • Exit guide plate motor defective • Exit guide plate HP sensor defective • Exit guide plate open sensor defective 500-sheet Finisher • Output tray motor defective • Tray upper limit sensor defective