Code: 547
Description: Zero cross signal error
One of the following occurred: 1) The fusing relay remained off for 50 ms after power on and continued to remain off after the after 3 attempts to detect the zero-cross signal. 2) During 11 zero-cross signal detections, two zero-cross signal detections were below 44 Hz. 3) The zero-cross signal could not be detected within 3 sec. after the fusing relay switched on.
One of the following occurred: 1) The fusing relay remained off for 50 ms after power on and continued to remain off after the after 3 attempts to detect the zero-cross signal. 2) During 11 zero-cross signal detections, two zero-cross signal detections were below 44 Hz. 3) The zero-cross signal could not be detected within 3 sec. after the fusing relay switched on.
Causes: • Switch the main switch off and on • Defective fusing relay, replace the PSU