Code: E001-00FF
Description: The rise in the temperature of the fixing assembly is excessive. There is an open circuit or poor contact in the following: main thermistor (THM1, THM2, THM3), sub thermistor (THM4, THM5, THM6), or heater (H1, H2, H3, H4). The AC driver PCB or the DC controller PCB is faulty.
When the cause (Detailed code) cannot be found in the DC controller PCB input-port as DC controller PCB detects instantly an abnormal signal from the thermistor.
When the cause (Detailed code) cannot be found in the DC controller PCB input-port as DC controller PCB detects instantly an abnormal signal from the thermistor.
Remedy: After releasing the error with the procedure of COPIER>FUNCTION>CLEAR>ERR, 1. Turn off the switch of control panel. 2. Turn off the switch of main power. 3. Turn on the switch of main power. a. When the machine returns, Check the interconnection between the DC controller PCB and the thermistor. b. When the machine does not return, Follow the instruction the error (Detailed) code shows on the control panel.