Code: E000-0011
Description: At power-on, the rise in the temperature of the fixing assembly is not high enough. The main thermistor (THM1, THM2, THM3), thermal switch (TP1, TP2, TP3), or heater (H1, H2, H3, H4) has an open circuit or poor contact. The AC drive PCB or the DC controller PCB is faulty.
The temperature reaches 50 deg C, but does not reach 80 deg C within 300 sec.
The temperature reaches 50 deg C, but does not reach 80 deg C within 300 sec.
Remedy: Check for an open circuit and poor contact in the main thermistor, thermal switch, and heater; then, reset in service mode: COPIER>FUNCTION>CLEAR>ERR.