Code: E000-0026
Description: At power-on, the rise in the temperature of the fixing assembly is not high enough. The main thermistor (THM1, THM2, THM3), thermal switch (TP1, TP2, TP3), or heater (H1, H2, H3, H4) has an open circuit or poor contact. The AC drive PCB or the DC controller PCB is faulty.
The temperature reaches 200 deg C, but does not reach 230 deg C within 180 sec. If the outside heating roller is in contact, within 400 sec
The temperature reaches 200 deg C, but does not reach 230 deg C within 180 sec. If the outside heating roller is in contact, within 400 sec
Remedy: Check for an open circuit and poor contact in the main thermistor, thermal switch, and heater; then, reset in service mode: COPIER>FUNCTION>CLEAR>ERR.