Code: E004-000F
Description: There is an error in the fixing assembly protection circuit. There is an open circuit or poor contact in the main thermistor (THM1, THM2, THM3) or sub thermistor (TH4, THM5, THM6). The AC driver PCB or the DC controller PCB has a fault.
There is an SSR error in the outside heating roller heater, fixing sub heater, fixing main heater, or contact heater.
There is an SSR error in the outside heating roller heater, fixing sub heater, fixing main heater, or contact heater.
Remedy: Check the main thermistor and the sub thermistor for an open circuit and poor contact; then, reset in service mode: COPIER>FUNCTION>CLEAR>ERR.