Code: 231
Description: FGATE timeout
231-001: Y 231-002: M 231-003: C 231-004: K When LD units emit laser beams to print a job, the feedback signal stays Low. The signal becomes High after laser exposure for a page is completed. The SC code is detected in the following cases: • When the feedback signal stays Low 7 seconds after completing the laser exposure, or • When the feedback signal stays Low until the laser exposure timing for the next page in multi-page print mode.
231-001: Y 231-002: M 231-003: C 231-004: K When LD units emit laser beams to print a job, the feedback signal stays Low. The signal becomes High after laser exposure for a page is completed. The SC code is detected in the following cases: • When the feedback signal stays Low 7 seconds after completing the laser exposure, or • When the feedback signal stays Low until the laser exposure timing for the next page in multi-page print mode.
Causes: • Poor connection between BCU and LD units • Defective BCU • Defective LD unit