Code: E354-0002
Description: Serial No. mismatch
In the absence of an error, the soft ID PCB has been replaced with a new PCB and, in addition, the following conditions exist at the same time: - the soft IDs of the following pairs are not identical: SEEPROM and SRAM1, SEEPROM and SRAM2, SEEPROM and FRAM. - FRAM is not of the initialization pattern (i.e., the value of the check sum area is '1' but the result of computation of the counter area check sum is not '1'). - the soft IDs of the following are all identical: SRAM1, SRAM2, SRAM.
In the absence of an error, the soft ID PCB has been replaced with a new PCB and, in addition, the following conditions exist at the same time: - the soft IDs of the following pairs are not identical: SEEPROM and SRAM1, SEEPROM and SRAM2, SEEPROM and FRAM. - FRAM is not of the initialization pattern (i.e., the value of the check sum area is '1' but the result of computation of the counter area check sum is not '1'). - the soft IDs of the following are all identical: SRAM1, SRAM2, SRAM.
Remedy: A mistake is likely to have been made in the course of counter PCB replacement; as a result, E355 is likely to have occurred thereafter, not permitting recovery despite an attempt to reset E355.