Code: E001-0001
Description: The rise in the temperature of the fixing assembly is excessive. There is an open circuit or poor contact in the following: main thermistor (THM1, THM2, THM3), sub thermistor (THM4, THM5, THM6), or heater (H1, H2, H3, H4). The AC driver PCB or the DC controller PCB is faulty.
The rise in the temperature of the fixing roller is excessive.
The rise in the temperature of the fixing roller is excessive.
Remedy: Check the main thermistor, sub thermistor, and heater for an open circuit and poor contact; then, reset in service mode: COPIER>FUNCTION>CLEAR>ERR.