Code: E110
Description: scanner unit fault
Remedy: 1 . The connector of the BD signal line has poor contact. Action: Correct the connection of the connector J908 on the BD PCB and the connector J102 on the DC controller PCB. 2 . The laser/scanner unit fault (BD) signal is not generated properly. Action: Replace the laser/scanner unit. 3 . The connector of the scanner motor (M102) drive signal line has poor contact. Action: Correct the connection of the connector J907 on the scanner driver PCB and the connector J102 on the DC controller PCB. If the fault cannot be corrected, replace the scanner unit. 4 . The DC controller PCB is faulty. Action: Replace the DC controller PCB.