Code: 10.1
Display: 10.1 ERROR FUSER CALL FOR SERVICE
Description: Fixing unit failure (abnormal low temperature
Remedy: 1. The rated voltage of the fixing unit installed in the printer differs from the line voltage. Action: Replace the fixing unit. 2. The thermistor is dirty. Action: If the thermistor contact area of the upper fixing roller is dirty, clean it. 3. The thermistor is not installed correctly. Action: If the thermistor is not evenly contacting the upper fixing roller, re-install the thermistor correctly. 4. The thermistor wire is broken. Action: Turn the power OFF and remove the fixing unit. Measure the resistance between the fixing unit connector J50B-5 (FSRTH) and J50B-4 (GNDTH). If the resistance is not between about 190kom and 290kom (room temperature of 25°C), check the wiring from connector J222 on the DC controller PCB to the thermistor. If it is normal, replace the thermistor. 5. The main heater wire is broken. Action: Remove the fixing unit. If there is no continuity between the fixing unit connector J50-3 (FSRN1: the upper right terminal of the left connector) and J51-5 (FSRN2: the upper right terminal of the right connector), replace the main heater. 6. The sub heater wire is broken. Action: Remove the fixing unit. If there is no continuity between the fixing unit connector J50-4 (FSRL1: the lower right terminal of the left connector) and J51-6 (FSRL2: the lower right terminal of the right connector), replace the sub heater. 7. The thermoswitch is open. Action: Remove the fixing unit and wiring cover. If there is no continuity between thermoswitch terminals, replace the thermoswitch. 8. The fixing unit drive circuit is defective. Action: Replace the power supply unit. 9. The DC controller PCB is defective. Action: Replace the DC controller PCB.