Mã lỗi E001 — Canon LBP5200

Code: E001

Display: E001
Description: Fixing Unit Failure (Abnormally high temperature)
Remedy: 1) Shorted main thermistor Action: Measure resistance between the J119-4 and J119-5 on the DC controller PCB. If resistance is not within 350 kÙ to 520 kÙ (at room temperature of 25 °C), check the cables from the J201 for the fixing unit to J204 for the main thermistor. If nothing is wrong with the cables, replace the fixing film unit. 2) Shorted sub thermistor Action: Measure resistance between the J119-2 and J119-3 on the DC controller PCB. If resistance is not within 360 k to 530 k (at room temperature of 25 °C),check the cables from the J201 for the fixing unit to J205 for the sub thermistor. If nothing is wrong with the cables, replace the fixing film unit. 3) Defective power supply unit Action: Replace it. 4) Defective DC controller PCB Action: Replace it.