Code: E002
Display: E002
Description: Fixing Unit Failure (abnormally low temperature)
Remedy: 1) Broken main thermistor Action: Measure resistance between the J119-4 and J119-5 on the DC controller PCB. If the result is not within 350 k to 520 k (at room temperature of 25 °C), check the cables from the J201 for the fixing unit to J204 for the sub thermistor. If nothing is wrong with it, replace the fixing film unit. 2) Broken sub thermistor Action: Measure resistance between the J119-2 and J119-3 on the DC controller PCB. If the result is not within 360 k to 530 k (at room temperature of 25 °C), check the cables from the J201 for the fixing unit to J205 for the sub thermistor. If nothing is wrong with the cables, replace the fixing film unit. 3) Broken fixing heater Action: If the connector for the power supply unit has no continuity between J302-1 and J302-3, replace the fixing film unit. 4) Poor contact in connectors Action: Reconnect the J119 on the DC controller PCB, J302 for the power supply unit, and J201 for the fixing unit. 5) Defective power supply unit Action: Replace it. 6) Defective DC controller PCB Action: Replace it.