Description: Abnormally high temperature in fixing unit
Causes: The detected temperature of the main thermistor is 225 deg C (equivalent to approx. 0.84V) or higher for 0.5 sec. or longer. Cause: Main thermistor defect, DC controller PCB defect
Remedy: - Check the connector of the low-voltage power supply PCB. - Replace the fixing film unit. - Replace the DC controller PCB.