Causes: Error between DC controller PCB and main controller PCB. Cause Failure in connection between PCB, failure in DC controller PCB, failure in controller PCB.
Remedy: - Check the connection of the connector of the DC controller PCB and controller PCB - Replace the DC controller PCB - Replace the controller PCB