Code: E584-0002
Description: - Shutter drive motor or finisher controller PCB failure
- Shutter open detection sensor failure
- Shutter clutch failure
- The shutter open sensor did not turn off when 1000 ms have lapsed since the
shutter unit had performed close operation, resulting in incomplete close operation.
- Shutter open detection sensor failure
- Shutter clutch failure
- The shutter open sensor did not turn off when 1000 ms have lapsed since the
shutter unit had performed close operation, resulting in incomplete close operation.
Remedy: - Check the connector of the shutter open sensor. - Check the connector of the shutter clutch. - Check the connector of the shutter motor. - Replace the shutter open sensor. - Replace the shutter clutch. - Replace the shutter drive motor. - Replace the finisher controller PCB.