Mã lỗi 920 ... 925 — Lexmark T634

Code: 920 ... 925

Description: 920 Fuser Error Indicates that the fuser is below temperature when printing. 921 Fuser Error Indicates that the fuser is below standby temperature when the printer is idle 922 Fuser Error Fuser failed to reach standby temperature 923 Fuser Error Fuser is too hot during printing or when printer is idle. 924 Fuser Error An open circuit has been detected in the Fuser Thermistor Circuit 925 Fuser Error Wrong fuser lamp installed.
Remedy: Cold fuser service check
Error codes 920, 921, and 922 may display for a cold fuser failure. A 920 error caused by low line voltage can sometimes be cleared by turning the machine off and then on again. A 925 service error indicates the wrong fuser lamp is installed. Be sure the correct type of fuser lamp is installed. If the correct lamp is installed and a 925 error remains, the problem may be due to the following: • The fuser may have reached standby temperature too quickly. • The line voltage may be above the maximum rating for the printer. Note: A 920, 921 or 922 fuser error may be caused by an incorrectly mounted thermistor.
1 Fuser lamp (incorrect lamp/ 925 Service Error) Install the correct voltage and wattage lamp or fuser assembly. See “Fuser assembly removal”. If the correct fuser lamp is installed and the 925 error remains, the fuser may have reached standby temperature too quickly. Check that the line voltage is not exceeding the maximum rating for the printer. 2 Fuser lamp fuser top cover assembly Observe the lamp through the left side frame. If the lamp does not come on, do the following: • Remove the redrive assembly. • Remove the fuser assembly, disconnect the LVPS to fuser AC cable from the fuser assembly, and remove the fuser. See “Fuser assembly removal”. • Verify that the lamp is installed correctly. If correct, check the continuity of the fuser top cover assembly by verifying the lamp contacts on the right contact assembly. If incorrect, check continuity of the fuser lamp. If incorrect, replace the lamp. If correct, replace the fuser top cover assembly. 3 LVPS LVPS to fuser AC cable CAUTION: When taking measurements for AC power, observe all safety precautions. Measure the AC line voltage between the two connectors on the fuser end of the LVPS to fuser AC cable. If the voltage is incorrect, turn the power off, and remove the LVPS. Measure the AC line voltage between pins CN1-1 and CN1-3 on the board. If correct, check the continuity of the LVPS to fuser AC cable. If incorrect, replace the cable. If the AC line voltage at CN1 is incorrect, check fuse F2. If the fuse is blown, replace the fuse. If the fuse is not blown, replace the LVPS assembly. 4 Fuser top cover assembly (assembly includes thermistor and thermal fuses) Disconnect the thermistor cable from the fuser control board at J6. Resistance: • HOT J2-1–J2-2 <10K ohms • COLD approximately 450K ohms If the resistance is incorrect, replace the fuser top cover assembly. If the resistance is correct, check each pin of J6 to ground. If there is continuity, replace the fuser cover assembly. See “Fuser cover removal”.
Hot fuser service check
Error Code 923: Indicates the fuser is too hot during printing or when the printer is idle. Error code 924: Indicates an open circuit has been detected in the fuser thermistor circuit. Note: Check the fuser sub error codes to help diagnose between a 923 and 924 error.
1 Fuser cover assembly (assembly includes thermistor and thermal fuses) Check for damage to the thermistor assembly. If damage is found, replace the fuser top cover assembly. If no damage is found, check the resistance of the thermistor between pins J6-1 and J6-2 on the cable. • HOT < 10K ohms • COLD = approximately 450K ohms If the resistance is incorrect, replace the fuser top cover assembly. If the resistance is correct, check each pin of J6 to ground. If there is continuity, replace the fuser cover assembly. See “Fuser cover removal”. 2 Fuser assembly Check for continuity between J6-1 and J1-2 and between J6-2 and J1-3. If incorrect, replace the fuser assembly. If correct, go to step 3. 3 Fuser to system board DC cable Check the continuity of the cable. If incorrect, replace the cable. If correct, go to step 4. 4 System board Measure the voltage on J14-3 on the system board. The voltage should change from approximately +2.5 V dc with the thermistor cold to approximately +1.6 V dc when the thermistor is hot. If incorrect, replace the system board. If correct, go to step 5. 5 Fuser hot roll Fuser hot roll bearings Fuser backup roll bearings Fuser backup roll Fuser mechanical parts Examine the fuser assembly for signs of overheating or damage. Check the hot roll and backup roll for signs of excessive toner, label glue, labels, or other contaminants. If problems are found, replace the fuser assembly.