Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 920.00 — Lexmark W850n

Code: 920.00

Display: 920.00 Service fuser error
Description: Fuser unit assembly on time failure
Causes: During the warm-up period, the control thermistor does not detect the ready temperature even when the specified time is passed after the main lamp is turned on. During the standby period, the control thermistor does not detect the specified temperature even when the specified time is passed after the main lamp is on. During the standby period, the control thermistor does not detect the specified temperature even when the specified time is passed after the sub lamp in on. During idling, after power-on, the control thermistor does not detect the idling stop temperature even after the specified time is passed. During print, the control thermistor does not detect the specified temperature even when the specified time is passed after the main lamp is turned on. During print, the control thermistor does not detect the specified temperature even when the specified time is passed after the sub lamp is turned on.