Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 841.00...841.99 — Lexmark X203

Code: 841.00...841.99

Description: 841.00 Image Pipeline 841.01 Service image processing unit: AFE register mismatch 841.02 841.03 Service image processing unit: SCNCHN DMA 841.04 Service image processing unit: new line too soon interrupt 841.07 Service image processing unit: tonal data overrun 841.09 Service image processing unit: image processing too slow 841.96 System time out: SIZAR out of band interrupt 841.97 Service image processing unit: output data uncollected 841.98 Service image processing unit: SCNCHN DMA underrun 841.99 Service image processing unit interrupt handler delayed crash
Remedy: Flatbed Controller card Ensure that connectors J15, J1, and J5 are properly connected. Inspect the ribbon cable connection on CIS for proper connection. If connector J15 is properly connected, verify the following voltages on the controller card. Check pin 9 for +3.3V, pins 11, 13, and 15 for +5V. Pins 3, 6, and 8 are ground. If connector J1 is properly connected, verify the following voltages on the controller card. Check pin 19 for +12V and pin 20 for +5V. If voltages are present, replace the flatbed FRU. If there are voltage irregularities, replace the controller card.