Mã lỗi 950.xx — Lexmark X203n

Code: 950.xx

Description: Mismatch between EEPROM and mirror memory Note: A new controller board or operator panel has been installed, and has not been properly prepared for this use. Install a new note. Do not install both the controller board and the operator panel at the same time without a POR in between.
Remedy: Install a new controller bored or operator panel. See “Controller card service check” or “Operator panel service check”.
Operator panel Controller card Buttons Check connector J4, pin 2 for 3.3 V. If the voltage is present, replace the operator panel. If the voltage is not present, replace the controller card. Perform the panel test and button tests found in diagnostics. See “Panel Test” and“Button Test”. If the tests fail, replace the operator panel. Lights If the lights don’t illuminate, make sure the cable is properly connected to the controller card and the operator panel. Ensure the controller card has input voltage to it. Verify +24 V dc on cable pins 8 and 9 at J22. • Check for +5 V dc at J4, pin 1. See “Controller card service check” or page 4 for more information. • If these voltages are not correct, replace the controller card. • If these voltages are correct, replace the operator panel. If more than one light does not turn on or an individual light stays on solid during POST, replace the operator panel. If all lights are dim and operate erratically during POST or all lights come on and stay on solid during POST, replace the FRUs in the following order one at a time: • Controller card • Operator panel

← Xem tất cả mã lỗi Lexmark X203n

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie