Code: 844.01...846.07
Description: 844.01 Rear scan module output level error 844.02 Front scan module lamp level too low Front Mono channel, Front Color channels, Front Red channel, Front Green channel, and/or Front Blue channel is detected to have low lamp level. 844.03 Rear scan module lamp level too low Rear Mono channel, Rear Color channels, Rear Red channel, Rear Green channel, and/or Rear Blue channel is detected to have low lamp level. 845.yy Scanner Failure CIS failure 845 Front scan module cable failure or SCC card failure CIS channel failure. Check each channel(mono, R, G, B) for identical values indicating bad cable and/or SCC card. Excessive noise test for the dark data indicating some sort of CIS or analog electronics issue on that channel or channels. 845.01 Rear scan module cable failure or SCC card failure CIS channel failure. Check each channel(mono, R, G, B) for identical values indicating bad cable and/or SCC card. Excessive noise test for the dark data indicating some sort of CIS or analog electronics issue on that channel or channels. 845.02 Cable / SCC Failure Front scan module connector or cable failure 845.03 Cable / SCC Failure Rear scan module connector or cable failure 845.04 Cable Failure The connector cable is defective. 846.07 Front magnification exceeds limits Rear excessive variability for Mono, Red, Green, or Blue
Remedy: Flatbed Controller card Ensure that connectors J15, J1, and J5 are properly connected. Inspect the ribbon cable connection on CIS for proper connection. If connector J15 is properly connected, verify the following voltages on the controller card. Check pin 9 for +3.3V, pins 11, 13, and 15 for +5V. Pins 3, 6, and 8 are ground. If connector J1 is properly connected, verify the following voltages on the controller card. Check pin 19 for +12V and pin 20 for +5V. If voltages are present, replace the flatbed FRU. If there are voltage irregularities, replace the controller card.