Mã lỗi 200.16, 200.17 — Lexmark X466de

Code: 200.16, 200.17

Description: 200.16 Transport motor error detected 200.17 Took too long to ramp up transport motor
Remedy: Main motor gear drive Main motor cable LVPS/HVPS Controller board Warning: Do not replace the operator panel and controller board at the same time. Each card contains the printer settings. When either of these cards is new, it obtains the settings from the other card. Settings are lost when both are new and replaced at the same time. Turn off the printer, and unplug the main motor cable at J19. Turn on the printer, and check for the following voltages at J19: Verify ground at pin 5 for both the card and cable. •If these voltages are correct, then check the main motor cable for continuity. - Remove the left side cover to access the connector on the motor. - If continuity exists on each wire, then replace the main motor gear drive which includes the motor. - If continuity does not exist on one or more of the wires, then call the next level of support. •If these voltages are not correct, then see “Controller board connector pin values”, or replace the controller board. See “Controller board removal”.